Sapphire infusion pumps are small in size yet big in performance. Offering tailored solutions for a variety of infusion needs including hospitalization pain nutrition prehospital transpiration ambulatory and home infusion in a single pump. Sapphire solutions are designed to enhance patient care. Sapphire’s quick setup and intuitive
Choose from intravenous infusion sets with needles for direct access to the bloodstream or needleless infusion sets with a female Luer connector to attach to an IV catheter system IV bag or administration set for a controlled medication delivery rate.
Infusion Pumps TE 171/TE 172 TE 135 Clamp color orange 2 way spike SURPLUG x 1 0.2 µ filter Lock connector 2 way spike SURPLUG x1 0.2µ filter Lock connector Surplug Administration Set Surplug Administration Set TI PU200WY TI PU300WY TI PU200WY01 TI PU300WY01 TI PJ300WY01 SP PF306WY01 TI PU200W TI PU300W TI PU200WN01
Description Warranty Information IV Administration Infusion Pump Set. 0 Y site. These sets are designed for use with the Baxter FloGard 6201 6301. Case of 50 sets These sets are designed for use with the Baxter FloGard 6201 6301.
Sep 09 2021 The PMI Flow Regulator IV set is the safe accurate and cost effective solution to costly IV pump infusions. Our IV administration set offers consistency and accuracy during gravity fed delivery of medications. Designed with a universal vented spike 100 inches of kink free tubing and a smooth adjusting dial our flow regulator will accurately
Aug 13 2020 The IV infusion pumps provide hard and soft dose limits and safety practice guidelines to aid in safe medication administration Lynn 2011 . IV medications may also be given by gravity infusion in which case the health care provider must calculate the infusion rate for drops per minute. The best practice for piggyback infusions is to use an
York during the spring 2020 COVID 19 surge the relocation of smart IV infusion pumps outside of patient rooms. The goals of this innovation were to improve delivery of care conserve personal protective equipment limit the spread of the virus and protect staff from exposure. The authors discuss the initial concerns that arose regarding the safety and efficacy of this practice the
Semistructured interviews with nurses highlighted the impact of set design on nursing workflow when moving between gravity fed and pump based administration. Use of interchangeable single design IV sets across gravity and automated infusions minimizes disruptions to closed systems may reduce nurses being distracted from patients clinical
Feb 11 2015 After the IV bag is spiked with the IV administration set the IV solution/fluid flows through the tubing to remove the air. The priming volume of IV administration sets vary by manufacturer and affected by the length of the tubing and any add on devices. The priming volume information can be found on the packaging label of the IV
Apr 08 2020 The first step to smart infusion pump and administration set conservation is for hospitals to develop a list of medications that absolutely require delivery via smart infusion pumps with an understanding that those not on the list may be administered using alternative means if necessary as described below.
Nimbus II EMS is a small lightweight smart and durable infusion pump making it a perfect candidate for emergency transport use. This pump is highly customizable with editable presets protocols and global safeguards and names. Included are industry standard operating modes such as weight based programming and continuous volume over time. Max.
smiths medical #21 7355 24 set tubing pump iv cadd 101in male luer bag spike add on anti siphon valve clamp injection site totm plastic 0. Dec 15 2020 13. Using the tubing with the blue filter spike the Lipid bag and prime the Lipid through the tubing until it comes to the end.
Description Anifusion IV pump is a veterinary specific pump. Meaning all features are designed specifically for animals which reduces setup time and speeds up recovery. Anifusion delivers the most accurate amount of fluid to your patients. Unaccounted for fluid spend could be costing you up to 10 of your hospitals’ fluid and medication
Jun 20 2011 For assessing the rate of intravenous infusions the observer would record the infusion pump rate or count the number of drops per minute delivered by the administration set along with noting the type of administration set used that is standard macro set 20 drops/min or paediatric set 60 drops/min.
May 01 2014 The mechanisms of the IV pump which have been around for more than 40 years are considered mature technology. However the electronics side is ever evolving. The earliest pumps needed a device to count the drops and only alarmed if the set infusion rate could not be achieved. Nowadays only about half the pumps on the market employ drop
Product Type IV Sets X. Set Type Plum Infusion Pump X. Set Sub Type. Blood Administration 3 Extension 1 Primary 16 Secondary 5 Solusets/Burettes 7 Solusets Burettes 1 Specialty 2 Backcheck Valve. No 18 Drip Size. 10 1 15 20 20 3 60 7
IV Administration Sets Intrafix Primeline Standard IV SetFor administering all kinds of infusions Intrapur Inline Infusion set with 0.2 µm inline IV filter Intrafix Safeset Premium IV Administration Set with AirStop and Primestop Intrafix SafeSet Flush IV Administration Set for improved drug application. For infusion by gravity.
There are 10 types of Sapphire administration sets. Learn what they are used for how they work and which one is best for you.
IV administration sets Our full portfolio of IV therapy products are designed to optimize infusion delivery reduce the risk of infection and protect vascular access sites. Platform interoperability Our interoperability solutions help you program infusions while avoiding manual programming steps that can cause errors.
Effect of intravenous infusion pumps versus gravity on platelet transfusion. The purpose of this study is to evaluate infusion pumps which are claimed to be suitable for blood products and to investigate the impact the pumps had on platelets Meess 2015 . Platelet concentrates are given to patients suffering with severe thrombocytopenia
Jan 28 2021 CADD Administration Sets with Air eliminating Filter. Online Support. Not available in all regions. Add to Brochure Remove Item. CADD Solis Infusion Systems Wireless connectivity and versatility for pain management. Learn more. For use with CADD Legacy CADD Prizm and CADD Solis pumps. Read Less.
Shop for Over 1 000 IV Administration and Infusion Supplies. When you shop eSurg for IV administration supplies and infusion sets you can rest assured you are receiving the highest quality products at the most competitive prices in the industry.. Find the IV administration supplies and infusion sets that meet your needs at eSurg.
Infusion Pumps and Clinical Software IV Sets X. Set Type Plum Infusion Pump X. Drip Size 20 X. Set Sub Type. Blood Administration 2 Solusets Burettes 1 Backcheck Valve. No 2 Filtered. Yes 3 Hand Pump. No 2 Latex Information. Yes 3 Nominal Length. 105.0 1 110.0 2 Non DEHP. Yes 3
These IV sets are designed for gravity use only IV tubing is not compatible with infusion pump administration systems Do not contain DEHP
Types of IV Infusion Pumps. The U.S. Food and Drug Administration better known as the FDA lists several different types of infusion pumps used in the modern medical environment.Some of the most common types of IV infusion pumps include the following Large volume infusion pumps These are capable of delivering large amounts of fluids to patients