Description. PRODUCT NO. TCBINF044G Our IV Administration Set with 0.2μm filter and flow regulator consists of a universal spike male swivel luer lock roller clamp drip chamber with 15μm filter and 0.2μm in line filter. Each set is individually blister packaged in quantities of 40 per box. 20 drops/mL One 1 Y injection site 6″ from distal end
Approx. Priming Volume from Stopcock to Patient 3.0 ml. Magnum Micro Delivery sets are designed to enable primary IV administration from a Medfusion Syringe Pump to deliver a flush after medication infusion and to administer drugs with short half lives that require precise continuity of flow.
Aug 04 2020 Filtered Extension Sets 0.22 Micron 1.2 Micron Filters. Available in any length the Microbore and Macrobore Extension Sets can be utilized with or without needle free connectors. These patient friendly non bonded needle free connectors can accommodate priming volumes from 0.3mL to 2.4mL.
106 2.7m CONTINU FLO Solution Set 0.22 Micron High Pressure Extended Life Filter a CLEARLINK Luer Activated Valve Male Luer Lock Adapter Approximately 10 drops per mL. Compatible with the FLO GARD 6201 and FLO GARD 6301 Series Pumps. Filter has passed bacterial and pyrogen retention testing for 96 hours. Contains DEHP. Fluid path is sterile.
92 IV SET 20 DROP 300ML WITH FLOW REGULATOR UNIVERSAL SPIKE 15 MICRON FILTER Y SITE50/CS. Login for Pricing. View Product. ITEM #RF5600.
Apr 02 2020 0.2 Micron Filter Removes particulate matter larger than 0.2 microns and virtually all fungi and bacteria. Often used as a final filter for air elimination. Notes BD filters are self priming. DO NOT INVERT FILTER.BD 0.2 micron filters contain Supor Polyethersulfone membranes which have low protein and drug binding characteristics.
Infusion Supplies Infusion chairs IV pole IV administration sets Polyvinyl chloride PVC infusion set with/without DEHP containing 0.2 or 0.22 micron polyethersulfone PES in line filter IV and catheters 3 mL saline syringes appropriately sized syringes alcohol wipes 2x2 gauze pads adhesive bandages
Administration Method Gravity 2C65710.22 Micron Upstream High Pressure Extended Life Filter 2 INTERLINK Injection Sites Male Luer Lock Adapter with Retractable Collar 10 drops per mL 105 Inch. Compatible with the
Baxter s CONTINU FLO Administration Solution Set has a non vented spike with as many as three 3 luer activated valves and a male luer lock adapter that s able to deliver approximately 10 drops per mL of solution for treatment. This 109 inch long solution set has a priming volume of 17.2 mL and has a non vented spike with a back check valve. The set also has three y sites
1W5019s Solution Set 20 drops/mL Interlink Y SIte 1 ea 15 micron disc filter with luer lock adapter3 93 2C6571s CONTINU FLO Solution Set 0.22 micron filter Interlink Y Site 2 ea with luer lock adapter back check valve2 3 105 2C8571s CONTINU FLO Solution Set 0.22 micron filter Clearlink Y Site 2 ea with luer lock adapter
DYNDTN1523 92 IV Administration Set w/ Flow Controller Universal Drip Chamber Pinch Clamp Flow Rotating Male Luer Lock 50/cs Drops/mL 15 Item No. Description Pkg DYNDTN1529 92 IV Administration Set w/ 1 Needle Free Y Site with Universal Drip Chamber Roller Clamp Rotating Male Luer Lock .22 Micron Filter Non Removable Slide
Aug 09 2014 Today was the first time I came across a pt that requires me to use the following for the Baxter IV pump Extension Set with 0.22 micron high pressure extended life filter and 1 INTERLINK injection site 6 from male Luer lock adapter
Oct 06 2009 Filters PFO opening between right and left atria Air eliminating filter 0.2 micron Some medications should NOT be filtered ex. amphotericin NOT for use with blood transfusions Check priming volume Should be changed every 96 hours Placed ‘closest to
0.22 micron IV Express filter Anti Free Flow Valve Approximate priming volume 16 ml INTRODUCTION 6 Z 800 Instructions for Use. P/N 800 IFU 6651 Rev. I FEATURES Flow Rates The Z 800 Infusion Pump flow rate range is from 1 to 1200 ml/h. Free Flow Protection
Oct 16 2019 I Medical Devices I.V. Administration and Secondary Sets consist of a universal vented or non vented spike male swivel luer lock roller clamp Y injection site located 6 from the distal end and drip chamber outfitted with a 15 micron filter. Sets are also available in models featuring a 0.22 micron air eliminating low protein binding
Experimental and clinical studies have proven that our IV in line filtration devices can retain particles air bubbles microorganisms and associated endotoxins. 5 7 Additionally the implementation of IV in line filters may improve patient outcomes and the overall hospital economic benefits by reducing the length of stay for ICU patients. 8 13 We have and continue
Our IV Administration Set with 0.22 Micron Filter and flow Regulator consists of a universal spike male swivel luer lock roller clamp flow regulator and drip chamber with a 0.22 micron filter. Each set is individually blister packaged in
Our IV Administration Set with 0.22 Micron Flter consists of a universal spike male swivel luer lock roller clamp and drip chamber with a 0.22 micron filter. Each set is individually blister packaged in quantities of 50 per box and features
Valve 90 inches from male Luer lock adapter. Sterilization method RadiationGamma. Filter has passed bacterial and pyrogen retention testing for 96 hours. Replace set per CDC guidelines. Part Number s ACT8570EA1 Each / Each. ACT8570CS48 Each / Case.
A wide selection of sets and components meet a variety of solution administration requirements Shop Kawasumi Gravity IV Administration Sets Vented at Fishersci Kawasumi Gravity IV Administration Sets Vented Vented set with 0.22 micron Fisher Scientific
SET IV ADMINISTRATION 20GTT 40INL SECONDARY DROP IN LINE DRIP CHAMBER FLOW REGULATOR W/0.22 MICRON FILTER BAG HANGER SPIROS SPIROS LATEX FREE DEHP FREE 50/CS Part Number ICU Medical CH3020 SKU Number CIA Sell Unit CASE Ships Within Special Order List Price 339.23 Qty Add to Cart Product Description
tubing on the filter. 3. Remove the protective cap from the end of the administration tubing. Be careful to keep the exposed end sterile. 4. Using a twisting motion attach the filter tubing to the administration set tubing. 5. When priming the IV tubing invert the filter to fill completely. 6. Wash hands thoroughly for at least 20 seconds
The Micro IV FilterIV Administration Sets is low priming volume and superior air elimination ensure accurate drug delivery Minimum Water Flow Rate 0.2 µm ≥ 2 mL/min at 91 cm 36 in. head pressure 0.8 µm ≥ 12 mL/min at 91 cm 36 in. head pressure
FILTERS Change with IV tubing. Use air eliminating type. 0.22 micron Routine meds/fluids. Completely bacteria retentive. 1.2 micron Parenteral nutrition/lipids in bag. Removes precipitates that may be masked by lipid emulsion. No filter Medications that cannot be filtered. SOLUTION CONTAINER Within 24 hours after being spiked.
Micro Delivery Administration Set Pinch Clamp Back Check Valve Anti Free Flow Stopcock 6 Detachable Extension 60 Small Bore Extension with 0.2 Micron Filter Male Luer Lock Non DEHP Formulation Latex Free Low Protein Binding Filter 3.0 mL 74 188 cm 25 1 33 6 60 6 MX448HLMG Vented / Non Vented Spike Mangum